What is this tool used for?
Use this preliminary sizing tool for a home operating without the electricity grid. It separates daily energy, simultaneous load, startup surge, battery autonomy and the solar energy needed to recharge the backup reserve.
How to use this calculator
Enter daily AC consumption, running and startup loads, the required surge duration, and worst-season design peak sun hours. Choose backup days and the number of sunny days allowed to restore the reserve while loads keep running. Enter battery voltage, DoD and separate conversion efficiencies. PV-side losses should exclude the inverter and battery losses already entered.
Understanding your results
Panels are rounded up to whole modules. Battery kWh and Ah describe nominal storage, not fully usable energy. Inverter kW, kVA and surge ratings are separate requirements. The controller figure is an output-current estimate only: verify cold string voltage, input current, MPPT range and manufacturer limits. A conservative all-energy-through-storage assumption is used; hourly weather simulation and equipment checks are still needed.
Számítási módszer
Az eredmény használata előtt
Conservative energy model: all daily consumption is assumed to cycle through storage. PV losses exclude the separately entered inverter and battery losses. Autonomy starts with a fully charged battery; recharge assumes consecutive days at the entered design sun hours while daily loads continue. This is preliminary sizing, not guaranteed year-round off-grid supply. Check worst-season weather, ageing and temperature derating, battery/BMS discharge and charge limits, controller cold Voc/Isc and MPPT range, string layout and protection separately. Controller amps alone do not establish compatibility.
What should I check before using this estimate?
Conservative energy model: all daily consumption is assumed to cycle through storage. PV losses exclude the separately entered inverter and battery losses. Autonomy starts with a fully charged battery; recharge assumes consecutive days at the entered design sun hours while daily loads continue. This is preliminary sizing, not guaranteed year-round off-grid supply. Check worst-season weather, ageing and temperature derating, battery/BMS discharge and charge limits, controller cold Voc/Isc and MPPT range, string layout and protection separately. Controller amps alone do not establish compatibility.
Tervezés folytatása
Összes kalkulátor →Terhelés és áramfogyasztás
Terhelés és áramfogyasztás. Add meg a saját adataidat a becsléshez. Az eszközök kiválasztása előtt nézd meg a számítás módját és korlátait.
Inverter méretezése
Inverter méretezése. Add meg a saját adataidat a becsléshez. Az eszközök kiválasztása előtt nézd meg a számítás módját és korlátait.