輸入參數
可編輯的範例值估算結果
即時計算結果最小 · 溫度 · Voc
214.63 V
最大 · 溫度 · Vmp
140.87 V
最小 · 溫度 · Vmp
184.76 V
Limit checks failed
0
這些結果供初步規劃使用。選購設備前,請核對計算假設。
系統不會自動取得位置或電價,計算以您輸入的資料為準。
如何使用這個計算工具
一次檢查一個MPPT輸入。填入板子參數、溫度和逆變器限制,確認是否超過電壓或電流範圍。
計算方法
Temperature-corrected voltage = series × reference voltage × [1 + coefficient / 100 × (cell temperature − 25)]. Compare cold Voc with absolute PV maximum; hot and cold Vmp with MPPT window. Compare parallel Imp and Isc with their separate current limits.
使用結果之前
Passing these selected checks is not full equipment approval. Verify startup voltage, permitted array wattage, irradiance/current correction factors, connector limits and manufacturer string-design rules. Inputs describe ONE MPPT, not combined independent MPPT channels.
What should I check before using this estimate?
Passing these selected checks is not full equipment approval. Verify startup voltage, permitted array wattage, irradiance/current correction factors, connector limits and manufacturer string-design rules. Inputs describe ONE MPPT, not combined independent MPPT channels.